Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Quantitative evaluation of deep convolutional neural network-based image denoising for low-dose computed tomography

Keisuke Usui; Koichi Ogawa; Masami Goto; Yasuaki Sakano; Shinsuke Kyougoku; Hiroyuki Daida (2021). Visual Computing for Industry, Biomedicine, and Art

DOI 10.1186/s42492-021-00087-9

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

AbstractTo minimize radiation risk, dose reduction is important in the diagnostic and therapeutic applications of computed tomography (CT). However, image noise degrades image quality owing to the reduced X-ray dose and a possible unacceptably reduced diagnostic performance. Deep learning approaches with convolutional neural networks (CNNs) have been proposed for natural image denoising; however, these approaches might introduce image blurring or loss of original gradients. The aim of this study was to compare the dose-dependent properties of a CNN-based denoising method for low-dose CT with those of other noise-reduction methods on unique CT noise-simulation images. To simulate a low-dose CT image, a Poisson noise distribution was introduced to normal-dose images while convoluting the CT unit-specific modulation transfer function. An abdominal CT of 100 images obtained from a public database was adopted, and simulated dose-reduction images were created from the original dose at equal 10-step dose-reduction intervals with a final dose of 1/100. These images were denoised using the denoising network structure of CNN (DnCNN) as the general CNN model and for transfer learning. To evaluate the image quality, image similarities determined by the structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were calculated for the denoised images. Significantly better denoising, in terms of SSIM and PSNR, was achieved by the DnCNN than by other image denoising methods, especially at the ultra-low-dose levels used to generate the 10% and 5% dose-equivalent images. Moreover, the developed CNN model can eliminate noise and maintain image sharpness at these dose levels and improve SSIM by approximately 10% from that of the original method. In contrast, under small dose-reduction conditions, this model also led to excessive smoothing of the images. In quantitative evaluations, the CNN denoising method improved the low-dose CT and prevented over-smoothing by tailoring the CNN model.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=2; title_english_share=0.1333; title_reads=english; abstract_words=308; abstract_english_function_words=109; abstract_english_share=0.3539; abstract_reads=english; language_check=metadata_listed