Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Sinogram-based tomography densification and denoising based on a physics-informed deep learning approach

Carlo Pezzoli; Marco Brando Mario Paracchini; Stefano Tubaro; Marco Marcon (2026). Biomedical Signal Processing and Control

DOI 10.1016/j.bspc.2026.110864

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Computed tomography (CT) is a widely used medical imaging technology that provides detailed information about the internal structures of the human body. Despite its effectiveness, CT relies on X-ray radiation, which can be harmful at high doses. To mitigate this risk, Low-Dose Computed Tomography has been developed as a safer alternative. This can be achieved either by reducing the radiation dose while maintaining a high number of projections, or by decreasing the number of projections without altering the X-ray power. Both strategies pose challenges during the reconstruction process: the former results in noisy sinograms, whereas the latter produces sparse sinograms. In this study, a novel CT reconstruction framework is proposed to address these challenges. A modular deep learning architecture, based on Generative Adversarial Networks (GANs) and Filtered Back Projection (FBP), is combined with a customized training procedure. The framework consists of a sinogram enhancement phase and a reconstruction phase. Specifically, the main novelty of the proposed approach lies in the implementation of FBP within the Physical Coherence Module (PCM), which acts as a layer of the network and serves as a bridge between the sinogram enhancement sub-network and the reconstruction sub-network. These components are trained both separately and jointly by means of a multitask loss function. Experimental results on synthetic and public datasets show improved reconstruction accuracy compared with traditional FBP and other advanced techniques for both denoising and sinogram densification tasks. The proposed framework enhances CT image detail while reducing radiation exposure.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=248; abstract_english_function_words=95; abstract_english_share=0.3831; abstract_reads=english; language_check=metadata_listed