Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Radiological and clinical outcome of screw placement in adolescent idiopathic scoliosis: evaluation with low-dose computed tomography
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
Posterior corrective surgery using "all pedicle screw construct" carries risk of neurovascular complications. The study aims were to assess the screw placement in patients with adolescent idiopathic scoliosis using CT with low-radiation dose, and to evaluate the clinical outcome in patients with misplaced pedicle screws. CTs of 49 consecutive patients (873 screws, 79% thoracic) were retrospectively evaluated by two independent radiologists. A new grading system was developed to distinguish between lateral, medial and anterior cortical perforations, endplate perforation and foraminal perforation. The grading system is based on whether the cortical violation is partial or total rather than on mm-basis. The overall rate of screw misplacement was 17% (n = 149): 8% were laterally placed and 6.1% were medially placed. The rates of anterior cortical, endplate and foraminal perforation were 1.5, 0.9, and 0.5%, respectively. Lateral cortical perforation was more frequent in the thoracic spine (P = 0.005), whereas other types of misplacement including medial cortical perforation were more frequent on the left and the concave side of scoliotic curves (P = 0.002 and 0.003). No neurovascular complications were reported. The association between the occurrence of screw misplacement and the Cobb angle was statistically significant (P = 0.037). Misplacements exceeding half screw diameter should be classified as unacceptable. Low-dose CT implies exposing these young individuals to a significantly lower radiation dose than do other protocols used in daily clinical practice. We recommend using low-dose CT and the grading system proposed here in the postoperative assessment of screw placement.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=233; abstract_english_function_words=80; abstract_english_share=0.3433; abstract_reads=english; language_check=metadata_listed