Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Baseline computed tomography screening and blood microRNA predict lung cancer risk and define adequate intervals in the BioMILD trial

Ugo Pastorino; Mattia Boeri; Stefano Sestini; Federica Sabia; Gianluca Milanese; Mario Silva; Paola Suatoni; Carla Verri; Anna Cantarutti; Nicola Sverzellati; Giovanni Corrao; Alfonso Vittorio Marchianò; Gabriella Sozzi (2022). Annals of Oncology

DOI 10.1016/j.annonc.2022.01.008

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Large randomized trials have demonstrated that lung cancer (LC) screening with low-dose computed tomography (LDCT) reduces LC mortality in heavy smokers. We previously showed in the MILD screening trial that the combination of a prespecified circulating microRNA (miRNA) signature classifier (MSC) and LDCT improves the accuracy of LDCT alone. The primary aim of the prospective BioMILD study was to assess the additional value of the blood MSC assay at the time of baseline LDCT with the goal of personalizing LC screening intervals. PATIENTS AND METHODS: The study enrolled 4119 volunteers from January 2013 to March 2016, with a median follow-up of 5.3 years. Baseline LDCT and miRNAs stratified participants into four groups: CT-/MSC- (n = 2664; 64.7%); CT-/MSC+ (n = 800; 19.4%); CT+/MSC- (n = 446; 10.8%); and CT+/MSC+ (n = 209; 5.1%). As per the protocol, those in the CT-/MSC- and CT-/MSC+ groups were allocated to LDCT repeat at 3-year and 1-year intervals; CT+ participants were allocated for 1-year or earlier intervals on the basis of LDCT features independent of MSC results. RESULTS: CT+ participants had a 15.8-fold higher 4-year LC incidence than CT- participants (95% confidence interval 10.34-24.05), and MSC+ participants had a 2.0-fold higher 4-year LC incidence than MSC- participants (95% confidence interval 1.40-2.90); there was no evidence that the MSC effect differed between CT+ and CT- participants. LC incidence at 4 years was 0.8% in CT-/MSC-, 1.1% in CT-/MSC+, 10.8% in CT+/MSC-, and 20.1% in CT+/MSC+ participants. LC mortality rates at 5 years in the four risk groups were 0.5 in CT-/MSC-, 1.5 in CT-/MSC+, 4.2 in CT+/MSC-, and 10.1 in CT+/MSC+. CONCLUSION: The combined use of LDCT and blood miRNAs at baseline predicts individual LC incidence and mortality, with a major effect of MSC for LDCT-positive individuals. These findings may have important implications in personalizing screening intervals.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=4; title_english_share=0.2105; title_reads=english; abstract_words=290; abstract_english_function_words=96; abstract_english_share=0.3310; abstract_reads=english; language_check=metadata_listed