Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Point-of-Care Breath Volatile Organic Compound Analysis as a Tool for Lung Cancer Screening: A Pilot Feasibility Study

Yakov Pichkar; Spiros Manolakos; Kaela M Phillips; Matthew B. Schabath; Ashish Chaudhary (2026). medRxiv

DOI 10.64898/2026.08.26.26361331

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Low-dose computed tomography (LDCT) screening reduces lung cancer mortality but is limited by low uptake and associated with high rates of false-positives and indeterminate-nodules. Breath volatile organic compound (VOC) analysis is a non-invasive candidate biomarker approach that could complement LDCT, but prior work has relied on laboratory-based high-resolution mass spectrometry (HRMS), limiting point-of-care deployment. Methods: In this pilot study, breath samples were collected from 40 patients with treatment-naïve, pathologically confirmed non-small cell lung cancer (NSCLC) and 25 lung-cancer-screening-eligible healthy controls. Paired samples were analyzed via a compact point-of-care GC-MS platform (CLARION) and a laboratory HRMS reference. Diagnostic classification models were built independently for each platform using elastic net logistic regression with leave-one-out cross-validation, and performance was evaluated by area under the receiver operating characteristic curve (AUC). Results: CLARION identified 103 VOCs across breath specimens, compared to over 900 identified by HRMS. Despite this difference in panel size, CLARION achieved diagnostic performance nearly identical to HRMS for distinguishing NSCLC cases from controls (AUC 0.864 vs. 0.863). Compared to controls, performance statistics were similar for early-stage NSCLC (AUC 0.854 vs. 0.841) and adenocarcinoma (AUC 0.770 vs. 0.787). VOCs of interest include p-cymene, phenol, propylbenzene, tetradecane, β-ocimene, 2,3-dihydro-indole, and 1-methylthio-(Z)-1-propene. Conclusion: A compact, point-of-care breath GC-MS platform achieved diagnostic performance for NSCLC detection comparable to a laboratory HRMS reference despite a substantially smaller detected VOC panel. These findings support continued development of point-of-care breath VOC testing as a non-invasive, field-deployable complement to LDCT-based lung cancer screening.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=5; title_english_share=0.2632; title_reads=english; abstract_words=267; abstract_english_function_words=62; abstract_english_share=0.2322; abstract_reads=english; language_check=metadata_listed