Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

FMDNet: Spatial‐frequency feature routing for low‐dose CT denoising

Yujie Yao; Y. M. Liang; W M Xiao; Zibo Zhou; Yaoxue Xu; Yonghao Pan; Xiao Xia (2026). Journal of Applied Clinical Medical Physics

DOI 10.1002/acm2.70656

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Low-dose computed tomography (LDCT) is widely used to reduce radiation exposure, but the reduced photon budget amplifies quantum noise and can introduce structured artifacts that obscure subtle boundaries and textures. Many deep learning denoisers process features in a single stream, which may encourage either over-smoothing of weak anatomical edges or unstable texture synthesis. PURPOSE: To develop an LDCT denoising network that explicitly routes coarse structural content and fine details through dedicated pathways, aiming to suppress noise while preserving anatomically meaningful high-frequency information. METHODS: We propose FMDNet, a frequency-aware encoder-decoder equipped with an explicit coarse/detail routing block. A fixed low-pass operator produces a coarse component, while the corresponding detail component is formed as an explicit residual (high = x-low). Each component is refined with depthwise operators and fused by a learned channel gate with channel attention. We evaluate FMDNet on the AAPM Mayo Clinic LDCT dataset and the LoDoPaB-CT benchmark under a reproducible HU-windowed protocol and supplement PSNR, SSIM, and RMSE with texture- and structure-oriented analyses including HU line profiles and noise power spectrum (NPS), together with volume-level paired tests and bootstrap confidence intervals on LoDoPaB-CT. RESULTS: Across both benchmarks, FMDNet achieves competitive quantitative fidelity and shows favorable results on complementary structure-/texture-oriented analyses. On Mayo, it improves mean PSNR, SSIM, and RMSE relative to strong learned baselines. On LoDoPaB-CT, volume-level analysis across 28 validation volumes confirms consistent improvements over Uformer with paired tests and bootstrap confidence intervals. Additional HU-profile and NPS analyses provide complementary evidence of improved texture preservation and local structural fidelity relative to comparative methods. CONCLUSIONS: Explicitly separating coarse and detail residual components in feature space provides a practical inductive bias for LDCT denoising. When combined with gated fusion and multi-scale supervision, this strategy improves quantitative fidelity and preserves fine structures without relying on adversarial texture synthesis; clinical diagnostic impact should be validated by reader studies.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=10; title_english_function_words=1; title_english_share=0.1000; title_reads=english; abstract_words=325; abstract_english_function_words=86; abstract_english_share=0.2646; abstract_reads=english; language_check=metadata_listed