Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Adaptive Physics-Guided Low-Dose CT Reconstruction with Residual Attention U-Net and Multi-Domain Structural Constraints

Sunil J S; Shruthi G; Prathima M N (2026). International Conference on Natural Language Processing and Computer Vision (ICNPCV)

DOI 10.1109/icnpcv69434.2026.11708969

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-Dose Computed Tomography (LDCT) has emerged as an important strategy for reducing radiation exposure during medical imaging. However, aggressive dose reduction introduces severe noise, streak artifacts, and structural degradation that adversely affect reconstruction quality and diagnostic reliability. Conventional reconstruction methods such as Filtered Back Projection (FBP) often exhibit limited robustness under extremely low-dose conditions, while many existing deep learning approaches rely on paired supervision and fixed regularization strategies that may reduce reconstruction stability across varying noise distributions. This paper presents an adaptive physics-guided deep reconstruction framework for LDCT imaging using a Residual Attention U-Net integrated with multi-domain structural constraints. The proposed framework performs image-domain reconstruction guided by projection-domain consistency using differentiable Radon physics guidance. The contribution of physics consistency during optimization is dynamically controlled by an adaptive weighting mechanism depending on reconstruction behaviour. In addition, structural similarity, edge-aware, and frequency-domain constraints are added to ensure anatomical boundary preservation and recovery of high-frequency textures under severe low-dose conditions. Simulated low-dose CT images were created using the Poisson-Gaussian noise model and used for experiments. Quantitative evaluation showed that the proposed framework achieved a mean PSNR of 32.30 dB and a mean SSIM of 0.8624, outperforming conventional FBP reconstruction, CNN baseline reconstruction, and standard U-Net reconstruction. The effectiveness of adaptive physics-guided optimization and multi-domain structural supervision in enhancing low-dose CT reconstruction quality and structural consistency is further confirmed by visual analysis, difference map evaluation, and ablation studies.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=249; abstract_english_function_words=60; abstract_english_share=0.2410; abstract_reads=english; language_check=metadata_listed