Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT

Lars Husmann; Fuminari Tatsugami; Ursina Aepli; Bernhard A. Herzog; Ines Valenta; Patrick Veit‐Haibach; Ronny R. Buechel; Aju Paul Pazhenkottil; Oliver Gaemperli; Nina Burkhard; Christophe Alain Wyss; Philipp Antonio Kaufmann (2009). International journal of cardiac imaging

DOI 10.1007/s10554-009-9490-x

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Electrocardiogram (ECG)-triggered, low dose computed tomography (CT) is increasingly used for attenuation correction in myocardial perfusion imaging (MPI) with SPECT. The purpose of the study was to assess the prevalence of relevant noncardiac findings in the field-of-view of such attenuation correction CT scans. Five hundred and eighty-two consecutive patients (211 female, 371 male; mean age: 64 +/- 11 years; BMI: 27.7 +/- 5.3 kg/m(2)) underwent 64-slice, ECG-triggered CT scanning for attenuation correction of MPI with SPECT. Relevant findings were defined as abnormalities that required clinical or radiological follow-up. Noncardiac findings were detected in 400 patients (68.7%). In 196 patients (33.7%) 226 relevant findings were detected. Findings included noncalcified pulmonary nodules (n = 156), interstitial lung disease (n = 6), pleural effusion (n = 20), pneumonia (n = 1), aortic aneurysm (n = 5), aortic dissection (n = 4), enlarged mediastinal lymph nodes (n = 5), mediastinal tumor (n = 3), breast abnormalities (n = 3), liver cirrhosis (n = 5), liver mass (n = 5), ascites (n = 5), splenomegaly (n = 2), renal mass (n = 1), hydronephrosis (n = 1), adrenal mass (n = 3), and bone metastasis (n = 1). As low dose 64-slice CT scans used for attenuation correction in MPI with SPECT reveal a high prevalence of noncardiac pathologic findings with potential clinical relevance, a systematic review of the CT scans appears mandatory.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=5; title_english_share=0.2500; title_reads=english; abstract_words=188; abstract_english_function_words=39; abstract_english_share=0.2074; abstract_reads=english; language_check=metadata_listed