Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

DRTNet: Hybrid Distribution Learning with LKAT Bottleneck for Low-Dose CT Denoising

Xiao Hu; Lingli Zhang; Chengwu Lu (2026). International Conference on Image Processing and Artificial Intelligence (ICIPAI)

DOI 10.1109/icipai70034.2026.11605586

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) typically employs a radiation dose lower than that of conventional CT for scanning. However, the reduction in dose also introduces stronger noise and artifacts, thereby affecting image quality and diagnostic reliability. To address this issue, this paper proposes DRTNet, a focused distribution-aware restoration framework for LDCT denoising. This method takes a Swin-Unet-style hierarchical encoder-decoder as its main body and enhances denoising performance through two targeted designs while maintaining the stability of the backbone structure. Firstly, this paper proposes HU-window-guided hybrid distribution learning, which combines full-image DFL with masked auxiliary DFL, where the auxiliary mask is deterministically generated from the target NDCT image according to a fixed HU window to strengthen residual distribution modeling in clinically relevant intensity regions. Secondly, this paper introduces the LKAT module at the bottleneck stage of the network, which enhances the context aggregation and representation ability of the deepest latent features through large-kernel depthwise convolutional spatial modulation. Through this design, DRTNet can simultaneously improve residual distribution learning and latent feature enhancement capabilities within a stable hierarchical encoder-decoder framework. This paper validated the proposed method on the 2016 NIH-AAPM-Mayo Clinic Low Dose CT Grand Challenge dataset. Experimental results show that the PSNR and SSIM of DRTNet reach 33.7092 dB and 0.9255 respectively, demonstrating its effectiveness in LDCT denoising.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=224; abstract_english_function_words=67; abstract_english_share=0.2991; abstract_reads=english; language_check=metadata_listed