Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
SPECT ventilation perfusion scanning with the addition of low‐dose CT for suspected pulmonary embolism
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
The addition of low-dose computed tomography (CT) to radionuclide ventilation perfusion single photon emission CT (SPECT) does indeed offer potential improvements in the diagnostic accuracy of patients with suspected acute pulmonary embolism, and Ling et al.1 should be thanked for their efforts. However, there are residual questions about the methods used by these authors, which may have been omitted because of editorial constraints but nevertheless merit attention. First, there is no information on the type of equipment used to acquire the CT data. This is important because one should not assume that all SPECT/CT devices are the same; some machines provide little diagnostic information beyond anatomic localisation, and it would be difficult to diagnose atelectasis, consolidation, small infarcts and other disorders, as the authors did in this series. This should be clearly stipulated because it would be unrealistic to expect that their results are applicable to all SPECT/CT devices. Second, although it is reasonable for non-radiology specialists to interpret low-dose CT, what quality assurance programs did the authors institute in order to convince readers that interreader and intrareader reproducibility is suitably high? This has important implications not only for their findings but also for the use of CT in other aspects of nuclear medicine. Third, it is interesting that the authors make only brief reference to d-dimer results. There may be little justification in using low-dose CT (indeed any sophisticated lung imaging) if the d-dimer result is negative in patients with a low-to-intermediate risk.2 How do their results look once the d-dimer result is considered? What proportion of the 29 patients with alternative diagnoses could have avoided lung SPECT/CT altogether? Readers of this journal are no doubt aware that even relatively low doses of ionising radiation may be harmful, and the risk can no longer be considered as a theoretic one.3, 4 Finally, it is disappointing that the authors have chosen to use a non-Australian source to suggest that after-hours radionuclide lung scanning is ‘limited in many institutions’.1 What evidence from Australian sources do they cite to support this statement?
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=15; title_english_function_words=4; title_english_share=0.2667; title_reads=english; abstract_words=352; abstract_english_function_words=156; abstract_english_share=0.4432; abstract_reads=english; language_check=metadata_listed