Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Standard versus low-dose computed tomography for assessment of acetabular fracture reduction using novel step and gap measurement technique

Abrianna S. Robles; Amit S. Piple; Donald J. DeSanto; Ashley Lamb; Stephen J. Gibbs; Nathanael D. Heckmann; Geoffrey S. Marecek (2023). European Journal of Orthopaedic Surgery & Traumatology

DOI 10.1007/s00590-023-03616-9

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: Quality of reduction is of paramount importance after acetabular fracture and is best assessed on computed tomography (CT). A recently proposed measurement technique for assessment of step and gap displacement is reproducible but has not been validated. The purpose of this study is to validate a well-established measurement technique against known displacements and to determine if it can be used with low dose CT. METHODS: Posterior wall acetabular fractures were created in 8 cadaveric hips and fixed at known step and gap displacements. CT was performed at multiple radiation doses for each hip. Four surgeons measured step and gap displacement for each hip at all doses, and the measurements were compared to known values. RESULTS: There were no significant differences in measurements across surgeons, and all measurements were found to have positive agreement. Measurement error < 1.5 mm was present in 58% of gap measurements and 46% of step measurements. Only for step measurements at a dose of 120 kVp did we observe a statistically significant measurement error. There was a significant difference in step measurements made by those with greater and those with fewer years in practice. CONCLUSION: Our study suggests this technique is valid and accurate across all doses. This is important as it may reduce the amount of radiation exposure for patients with acetabular fractures.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=214; abstract_english_function_words=95; abstract_english_share=0.4439; abstract_reads=english; language_check=metadata_listed