Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Edge Detection Attention Module in Pure Vision Transformer for Low-Dose X-Ray Computed Tomography Image Denoising

Luella Marcos; Paul Babyn; Javad Alirezaie (2025). Algorithms

DOI 10.3390/a18030134

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

X-ray computed tomography (CT) is vital for medical diagnostics, but frequent radiation exposure raises concerns, driving the adoption of low-dose CT (LDCT) to mitigate risks. However, LDCT often introduces noise, compromising diagnostic accuracy. This paper proposes a pure vision transformer (PViT) for LDCT denoising, enhanced with a gradient–Laplacian attention module (GLAM) to improve edge preservation and fine structural detail reconstruction. The model’s robustness was validated across five diverse datasets (piglet, head, abdomen, chest, thoracic), demonstrating consistent performance in preserving anatomical structures. Extensive ablation studies on attention configurations and loss functions further substantiated the contributions of each module. Quantitative evaluation using PSNR and SSIM, alongside radiologist assessment, confirmed significant noise suppression and sharper anatomical boundaries, particularly in regions with fine details such as organ interfaces and bone structures. Additionally, in benchmark comparisons against state-of-the-art LDCT models (RED-CNN, TED-Net, DSC-GAN, DRL-EMP) and traditional methods (BM3D), the model exhibited lower parameter and stable training performance. These findings highlight the model’s robustness, efficiency, and clinical applicability, making it a promising solution for improving LDCT image quality while maintaining computational efficiency.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=189; abstract_english_function_words=44; abstract_english_share=0.2328; abstract_reads=english; language_check=metadata_listed