Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low‐dose dobutamine stress test for the evaluation of cardiac function using ultrafast computed tomography

Osamu Yamaoka; Hideyuki Fujioka; Tuhn Haque; Yasuyuki Nakamura; Kenichi Mitsunami; Masahiko Kinoshita; Rikushi Morita; Kiyoshi Murata (1993). Clinical Cardiology

DOI 10.1002/clc.4960160604

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

AbstractHigh dose‐dobutamine (DOB) has been previously used as a pharmacological stress test to evaluate wall motion abnormalities. As a result, recent stress echocardiography with low‐dose DOB has been reported to be valuable for investigating stunned myocardium after thrombolysis. However, echocardiography requires an operator's skill and experience to evaluate wall motion abnormalities which are subjectively determined by the observer. In contrast, ultrafast computed tomography (UFCT) does not necessarily require extreme technical skill and experience. To evaluate the feasibility of stress UFCT with low‐dose DOB, we scanned 10 normal subjects along the short‐axis by 8‐slice‐multicine mode. After scanning at rest for baseline, we scanned during the administration of 4 and 8 m̈g/kg/min of DOB, respectively, for 5 min. Ejection fraction, contraction, and thickening were higher during 8 m̈g/kg/min of DOB than during 4 m̈g/kg/min of DOB and baseline, while the above values were higher during 4 m̈g/kg/min of DOB than during baseline (p < 0.01). It was possible to detect changes of cardiac function and wall motion due to low‐dose DOB by UFCT. We therefore conclude that UFCT is a reliable modality for evaluating cardiac function and wall motion for low‐dose DOB stress test because of its excellent spatial and contrast resolution.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=3; title_english_share=0.2000; title_reads=english; abstract_words=212; abstract_english_function_words=76; abstract_english_share=0.3585; abstract_reads=english; language_check=metadata_listed