LYSO scintillators coupled to phototransistors for orthogonal ray imaging: Experimental results at 4 and 6-MV linacs

Hugo Simões; Maria Cristina Battaglia; Miguel Capela; Ana Cavaco; Maria do Carmo Lopes; Paulo J. B. M. Rachinhas; Paula Soares; PauloC.P.S. Simoes; Paulo Crespo (2012). IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)

DOI 10.1109/nssmic.2012.6551885

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Orthogonal-ray imaging is a new technique under investigation by our groups. It shows good potential for (1) dose verification in external beam radiotherapy, and (2) very-low-dose computed tomography (CT-like) imaging. Here, we report on scanned, collimated measurements performed with LYSO crystals coupled to a phototransistor (PT), the latter fully substituting the photomultiplier tube (PMT). The very small dimensions of the PT allowed its insertion inside the collimation hole. Consequently, the well-known, harsh background flux characteristic of linacs used for radiotherapy is strongly reduced. This could allow for eliminating the need for PMT-dedicated shielding during the measurements, which provides a large reduction of complexity to all measurements. For this purpose, an electronics assembly was developed for signal formatting and acquisition. The setup was tested in 4-MV and 6-MV linacs, irradiating a PMMA phantom with a 80mm×80mm squared beam. Despite the correlation obtained between the experimental profiles and the simulated dose, the PT showed insufficient sensitivity to detect an air cavity inside the phantom. Due to this reason we conclude that the PT is not a good alternative to the PMT.

From OpenAlex.