Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Diagnostic Value of 123I-IMT SPECT in the Follow-up of Head and Neck Cancer

Michail Plotkin; Reinhard E. Wurm; David Kuczer; Peter Wust; Roger Michel; Timm Denecke; Juri Ruf; Lorenz Schlenger; Annet Bischoff; Roland Felix; Holger Amthauer (2006). Oncology Research and Treatment

DOI 10.1159/000092025

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Nuclear medicine imaging is increasingly used in the evaluation of tumors of the head and neck. In the current study, we assess the value of single-photon emission tomography (SPECT) using the amino acid tracer L-3-[123I]iodine-alpha-methyl-tyrosine (IMT) for the detection of recurrent head and neck cancer. PATIENTS AND METHODS: 45 consecutive patients with suspected recurrence of previously treated head and neck cancer were examined by IMT-SPECT using a dual head system with integrated low-dose computed tomography (CT). The accuracy of the IMT-SPECT was evaluated by correlating the findings with results of histology or clinical and CT/MRI (magnetic resonance imaging) follow-up examinations. RESULTS: The sensitivity, specificity and accuracy of IMT-SPECT in the detection of recurrent/persistent tumors were 83, 89 and 84.5%, respectively. The positive and negative predictive value amounted to 96.5 and 60%, respectively. CONCLUSION: IMT-SPECT using integrated low-dose CT appears to be a helpful complementary imaging tool for the detection of local recurrences and lymph node metastases of head and neck cancer and their differentiation from treatment-induced changes. The advantage of the method is the high positive predictive value in the diagnosis of relapsed tumors. However, a negative IMT-SPECT result does not exclude a recurrence.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=5; title_english_share=0.3333; title_reads=english; abstract_words=206; abstract_english_function_words=71; abstract_english_share=0.3447; abstract_reads=english; language_check=metadata_listed